Home> level meter >> UHZ-517C17 anti-corrosion UPVC Turning Column Magnetic Level Gauge
  • Product number:MC-000507006711
  • Product name: anti-corrosion UPVC Turning Column Magnetic Level Gauge
  • Product Type:UHZ-517C17
  • Product nameplate:SAIC
  • Project Category:level meter >>
  • Manufacturer:Shanghai Automation Instrumentation Co., Ltd.
  • Sales unit: Shanghai Automation Instrumentation Marketing Center
  • Information download:Click to enter the download page  
  • Introduction
  • Specifications
Level meter according to the buoyancy principle and principle of magnetic coupling work. When the measured liquid level container movements, the level gauge led tube also will lift the float, float within the permanent magnet passes through the magnetic coupling to the scene indicator, turning red column driver switch 180 °, when the liquid bits increases, the turn from white to red column, when the liquid level when the column turned from red to white, indicator of the red, white circles located at the medium level for the container and the actual height to achieve the level of instruction .
Scope
UHZ-517C17-type corrosion-resistant magnetic level gauge turned column applies to hydrochloric acid, sulfuric acid, etc. The measurement of inorganic corrosive liquids, high strength can be imported because the metal close to, particularly in
UPVC unique insulation, making the product suitable for outdoor water tank level measurement, the event will not freeze in winter inside.
Corrosive medium for liquid level measurement. In addition to on-site instruction can also be equipped with Remote transmitter, alarm (control switch), detection range. Instructions novel, intuitive reading, eye-catching, observing the direction indicator to change the angle according to user needs. Measurement range, from tank height restrictions, indicating complete separation of institutions and the measured medium, thus sealing, high reliability and safe. Simple structure, easy installation, low maintenance costs.
Range: 150 ~ 8000mm, 8000mm on the center or far from over conditions do not allow input level meter can be used over the length of sub-manufacturing.
Working pressure: 0.6MPa, 1.0 MPa
Operating temperature: -20 ~ 90

Accuracy: ± 10mm
Medium density: 0.5 ~ 2.0g/cm3
Environmental vibration: ≤ 0.5mm amplitude frequency ≤ 25Hz
Follow the speed: ≤ 0.08m / s
Medium viscosity: ≤ 0.4Pa.s, the viscosity of the medium or low to measure temperature and crystallization media, optional heating Jacketed Liquid Level
Process connection: bypassing the side mounting flange: DN25, PN1.0 convex
Flange Standard: HG20592 ~ 20635-97 other flange standards, please specify the user.
Material: bypass pipe:
UPVC
Float:
:UPVCPP,
,