Overload protection
Sensitivity: 2mV/V±0.1%
nonlinear: ±0.03%RO
Lag error: 0.02%RO
Repeatability error: 0.02% RO
excitation voltage: recommend 10V~12V(AC or DC)
max 20V(AC or DC)
zero output: ±1%RO
input resistance: 420Ω±40Ω
output resistance: 350Ω±5Ω
conductor: ф9.5 mm, 4 core, 3m cable
isolated resistance: >2000MΩ
temperature compensation range: -10~+70℃
working temperature: -20~+100℃
Temperature zero change: 0.02%RO/10℃
Temperature output change: 0.02%RO/10℃
Allowed overload capacity: 50%RC
notes: RO is rated output(excitation voltage=10V)
RL is rated load(measuring g=9.80665m/s2)
, ,