Output signal:4~20mADC
Header accuracy(proportion=1):±0.5%FS
hysteresis:±0.15FS
repeatability:±0.1%FS
dry standard:±0.2%FS
header indicating:±2.5%FS
performance of the whole instrument(proportion=1):
linear:±0.75%FS
hysteresis:0.4%FS
requirement of power supply:
standard transmitter:11~45VDC
SA and FM protection requirement 11~30VDC
PTB intrinsic safety requirement 11~2.5VDC
IE protection requirement 11~45VDC
Weight of standard float:general type:508 cm3 0.95kg
High-temperature type:638 cm3 1.00kg
range(unit:mm):500,800,1200,1600,2000
media proportion:0.4~1.0 g/cm3
minimum differential proportion:0.1(standard float)
Working pressure(unit:Mpa)
External float type:6.3,16
Internal float top type:6.3
Internal float side type:4
Flameproof Instrument:explosion-proof level ExdⅡCT4
Intrinsic Safety Instrument:explosion-proof level ExiaⅡCT4
Dust explosion-proof instrument:explosion-proof level DIP DDT13 safety barrier