My status
Manufacturer
Product search
November  1 , 2024  Friday
Home> temperature meter >> thermocouple >> WRNK-841nD Explosion-proof Intrinsically Safe Thermocouple
  • Product number:MC-000013002995
  • Product name:Explosion-proof Intrinsically Safe Thermocouple
  • Product Type:WRNK-841nD
  • Product nameplate:SAIC
  • Project Category:temperature meter >> thermocouple >>
  • Manufacturer:Shanghai Automation Instrumentation Co., Ltd.
  • Sales unit: Shanghai Automation Instrumentation Marketing Center
  • Information download:Click to enter the download page  
  • Introduction
  • Specifications
Industrial explosion-proof thermocouple or intrinsically safe thermocouple is a temperature sensor which is widely used in auto-control system. It can convert temperature parameter of controlled object into electrical signals and passes to the display, recording and regulating instruments through the temperature sensor. It is used to test, control and regulate system. In the chemical plant, it often accompanies by a variety of flammable, explosive and other chemical gases, steam, if you use common thermocouples, it is not safe and easy to cause explosion. So In these situations you must use the explosion-proof or intrinsically safe thermocouple as a temperature sensor. Our explosion-proof or intrinsically safe thermocouple products are applied in dIIBT4 ~ dIICT6, ibIIBT4, iaIIBT4, iaIICT6 temperature range group which has explosive gas.
model
Indexing No.
range
accuracy
Allowable error Δt ℃
WRN、WRNK
WRN2、WRNK2
K
0~800℃
±2.5℃ or ±0.75%t
WRE、WREK
WRE2、WREK2
E
0~600℃
±2.5℃ or ±0.75%t
Thermocouple Insulation Resistance
Testing voltage:DC 500±50V。
Temperature: 15~35℃
RH: 45%
Atmospheric pressure: 86~106kPa。
For the length more than 1 meter thermocouple: Rr·L>100 MΩ·m L>1m
Rr-resistance value, MΩ
L-length of thermocouple,m
for the length of the thermocouple≤ 1 m, insulation resistance value should be no less than 100 MΩ
Insulation resistance for armored thermocouple
Testing voltage: DC 500V。
Explosion-proof type and level group
Explosion-proof Group:dⅡBT4 or dⅡCT4 dⅡBT6 or dⅡCT6
Intrinsically safe Group:iaⅡBT4 or iaⅡCT4(Multi-style)
iaⅡBT6或iaⅡCT6(Multi-style)
Enclosure protection class: IP54
Model remark
Explosion-proof Intrinsically Safe Thermocouple
WR□-□□OA
W
R
Material of Temperature components
installation
Junction Box Type
O
A
thermometer
thermocouple
E)Nickel-chromium - copper-nickel
K)Ni-Cr - Ni-Si
2fixed screw
4fixed flange
6fixed thread Cone-shaped protection tube
4)explosion-proof, Intrinsically Safe-type
Design serial number
Remodeling number
 Explosion-proof Intrinsically Safe Armored Thermocouple
WR□K-□□O
W
R
Material of Temperature components
K
installation
Junction Box Type
O
thermometer
thermocouple
E)Nickel-chromium - copper-nickel
K)Ni-Cr - Ni-Si
armored
2)fixed thread
4)fixed flange
4)隔爆型、本安型
Design serial number
Explosion-proof Intrinsically Safe Thermocouple (Multi-action)
WR□K-□□□□□
W
R
Material of Temperature components
K
installation
Junction Box Type
铠装元件数
thermometer
thermocouple
E)
Nickel-chromium - copper-nickel
K)Ni-Cr - Ni-Si
armored
8)Fixed internal thread
4)
explosion suppression
3)3pairs
4.4 pairs
5.5 pairs
6.6 pairs